Volt Electric Heaters from LB White for 2023-2024
VOLT Electric Heaters from LB White (US markets ONLY).
VOLT Heaters are the equivilant of Patron Heaters, (Canada ONLY).
For Patron heaters for Canada follow this this LINK.
Equipmentland is the leading online authorized dealer, with all models available as supply is indicated.Units in stock for Fall 2023. Please call for availability after December 1, 2023.
Please let us know if we need to meet or beat a viable competitive price. Thank you.
FREE SHIPPING. For five or more and orders over $3500, fill out the order form for Quote for Payment Later, or call us. We will invoice for our easy payment by ACH method.
Volt (previously Patron) Electric Heaters from LB White 2023-2024
All Volt Heaters provide the following features:
– UL approved
– Industrial-grade fan
– Stainless jacketed heating coils
– Powder-coated steel housing
– High-quality sealed motor
– Quiet, combustion-free operation
– No fuel spills or odors
– Overheat protection at 104° F
– Integrated ambient thermostat from 32°F – 100°F
The following Volt models comprise the line:
Volt 1.5 (previously Patron E-1.5)
Power (kW) 1.5 Maximum Output per Hour (BTU/H) 5,100
Airflow (CFM) 116
Electrical Connection (VAC/Hz/Phase) 120/60/1
Amperage Draw (A) 12.5
Power Cord 3×16 AWG Plug NEMA 5-15P
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 14.5 Width (in.) 7.9 Height (in.) 12.2 Weight (lbs.) 13.7
Volt 3 (previously Patron E-3)
Power (kW) 3 Maximum Output per Hour (BTU/H) 10,200
Airflow (CFM) 205
Electrical Connection (VAC/Hz/Phase) 240/60/1
Amperage Draw (A) 12.5
Power Cord 3×16 AWG – Plug NEMA 6-15P
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 11.8 Width (in.) 10.2 Height (in.) 15.2 Weight (lbs.) 20.3
Volt 6 (previously Patron E-6)
Smaller cousin to Volt 9 (also 240V, 25 amp v 37.5 amp)
Power (kW) 6
Maximum Output per Hour (BTU/H) 20,500
Airflow (CFM) 250
Electrical Connection (VAC/Hz/Phase) 240/60/1
Amperage Draw (A) 25
Power Cord 3×8 AWG Plug NEMA 14-30P
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 19.5 Width (in.) 11.8 Height (in.) 17.3 Weight (lbs.) 32.9
Volt 9 (previously Patron E-9) – the most popular model
In Stock.
Power (kW) 9
Maximum Output per Hour (BTU/H) 30,700 @ 9kW (20,500 @ 6kW)
Airflow (CFM) 350
Electrical Connection (VAC/Hz/Phase) 240/60/1
Amperage Draw (A) 37.5 (25 @ 6kW)
Power Cord 3×8 AWG Plug NEMA 14-50P
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 23.0 Width (in.) 11.8 Height (in.) 18.3 Weight (lbs.) 39.9
It can be used in the most demanding of environments and has proven its abilities in hundreds of applications. The Volt 9 is a 240V unit and draws either 25 or 37.5 amps. This means it will run flawlessly off a stove receptacle. Make sure your receptacle is a NEMA 14-50P configuration, to ensure compatibility with our plug. The Volt9 produces a ton of heat, and disperses it in large areas with its 350 CFM fan. If not available, consider the Volt 6 which runs on the same circuit, just 25 amp rather than 37.5 amps of the Volt 9.
Volt 18.1 (previously Patron E-18.1)
Maximum Output per Hour (BTU/H)
(2 Stage Selector) 65,000 or 45,000
Airflow (CFM) 590
Electrical Connection (VAC/Hz/Phase) 240/60/1
Amperage Draw (A) Full: 81 Partial: 54
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 32.0 Width (in.) 14.0 Height (in.) 20.0 Weight (lbs.) 62.0
Volt 18.3 (previously Patron E-18.3)
Maximum Output per Hour (BTU/H)
(2 Stage Selector) 65,000 or 45,000
Airflow (CFM) 590
Electrical Connection (VAC/Hz/Phase) 240/60/3
Amperage Draw (A) Full: 47 Partial: 31
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 32.0 Width (in.) 14.0 Height (in.) 20.0 Weight (lbs.) 62.0
Volt 40 (previously Patron E-40)
Maximum Output per Hour (BTU/H)
(2 Stage Selector) 51,200 / 102,400 / 136,500
Airflow (CFM) 1,765
Electrical Connection (VAC/Hz/Phase) 480/60/3
Amperage Draw (A) Partial: 20 Partial: 40 Full: 50
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 46.0 Width (in.) 20.0 Height (in.) 25.0 Weight (lbs.) 125.0
Volt 60 (previously Patron E-60)
Maximum Output per Hour (BTU/H)
(2 Stage Selector) 82,000 / 164,000 / 205,000
Airflow (CFM) 1,765
Electrical Connection (VAC/Hz/Phase) 480/60/3
Amperage Draw (A) Partial: 30 Partial: 60 Full: 75
Ambient Thermostat Temperature Range 32 – 100 °F (0 – 40 °C)
Length (in.) 46.0 Width (in.) 20.0 Height (in.) 25.0 Weight (lbs.) 125.0
| Dimensions | 22 × 18 in |
|---|---|
| Volt Model | Volt 1.5, Volt 3, Volt 6, Volt 9, Volt 18-1, Volt 18-3, Volt 40, Volt 60 |